Comprehensive range of fire grille sizes. Gyproc FireLine 12.5mm is a fire resistant plasterboard that withstands fire for longer to allow for safe evacuation. Plasterboard Tiles; Insulated Tiles; . What is a 30 minute rated wall? The fire rating for the 1/2-inch drywall used throughout the rest of the home is 30 minutes. Fire Resistant Plasterboards benefit from superior fire resitance qualities. Knauf Fire Panel Plasterboard Tapered Edge 12.5mm x 2400mm x 1200mm Retail price 17.84 per sheet 14.87 ex. 12.5mm plasterboards are the normal these days, 9.5mm not really used that much now by the pro, but it does have a minimum of 30mins fire resistance, whether plastered or unplastered, it's not something I'd recommend though. fire protection, not the board on its own as its the whole wall system which is fire rated. Features include: Veneer, steel, aluminium, PVC, laminate, stone, glass and routered and/or applied beading facings. A Gyproc plasterboard with glass fibre and other additives in the core, which can be used in Gyproc partition, wall lining and ceiling systems for increased fire resistance. Since the middle of the last century, Gyprock plasterboard has gained tremendous popularity in the world of construction materials. Top edge of Grille should be no higher than 1,000mm (1m). One of the requirements is that the fire load is only on the room side, and the fire resistance classifi- cation is EI 30. Click & Collect from store within 30 minutes - FREE Product details. MASTERBOARD is a calcium silicate board reinforced with selected fibres and fillers. This Siniat wallboard conforms to the standards of BS EN 520. What is the difference between BS and BS EN fire resistance test standards for plasterboard partitions? 30-minute fire-rated ceiling access hatches are designed to be installed in self-contained fire protection false ceil- ings. For use in solid timber fire doors & solid block walls. The square edge boards are extremely compatible with MF ceilings to allow for skim plastering. Length: 2.4 m; Thickness: 12.50 mm; Width: 1 . Maximum height 2800mm SKU: PR-CSG-FR-30-30 Category: FIRE RATED RANGE Tags: 30/30, 40dB Rw, aluminium, fire rated, single glazed Description FRAMING DIMENSIONS: 30mm x 28mm aluminium head / abutment section (S01M) and 24mm x 25mm two part aluminium base section (S02 and S03). Each of these products can be used to enhance the fire performance of walls and ceilings in areas such as kitchens, school laboratories and specialist applications where the risk of fire is a concern. Fire-rated access panels 30 Minutes - 2 panels of 12.5 mm The 30-minute inspection access panel is specially de- signed for installation on service ducts. Ideal for fire-rated partitions such as in domestic separating walls, garages and corridors . The Gyprock range of fire resistant plasterboard includes; Fyrchek , Fyrchek MR, EC08 Impact, EC08 Impact MR and EC08 Complete. FireCrunch fire resistant building board offers protection to 90 minutes at 1000 deg C FRL 90/90/90. It can be left undecorated or can be easily decorated with paints, wallpapers . fire board? FlipFix Circular - 2 Hour Fire Rated Metal Faced Ceiling Access Panel, fitted with unique Flipfix Fitting Device, 2 Hour fire rated, 25mm wide Picture Frame, No Lock, Single Door Unit, Circular Door, Powder Coated RAL 9010 30% Gloss, the dimension stated View Product Make Enquiry Airtight & Acoustic 2 Hour Fire Rated - Slim Fit Fire-rated ceilingaccess hatch 30 Minutes - 1 panel of 18 mm. Anyone who says you'll get 60 mins f/r from 2 layers of 12.5mm wallboard alone is guilty of very wishful thinking. Plasterboard with a fire rating is available in two thicknesses: 12.5mm 15mm. You can't simply keep a steel beam exposed as there's no protection for it against fire - which would firstly invalidate your . This wallboard is available with square or tapered edges in a variety of sizes. The fire resistance capability is always expressed in minutes, usually from 30 minutes to two hours (120mins). What are the different sizes of fire-rated plasterboard? Although commonly referred to as fire rating, the correct term to describe the fire resistance of a building element is FRL (Fire Resistance Level). Masterboard is a multi-purpose board suitable for a variety of applications offering up to 30 minutes fire resistance Product code : 34B View more info Compare this product to another (up to 4 items) Quantity (Board) Add to quote Promat Promatect 250 Is fermacell a 30 min. Our ceiling tiles are engineered to meet the most stringent industry standards. 30 or 60 Structural Minute Fire Rating. The fire resistance capability is always expressed in minutes, usually from 30 minutes to two hours (120mins). Lined both sides with 12.5mm plasterboard. The guidance indicates that if installed correctly, 1x12.5mm fire plasterboard with a plaster skim will achieve 30 minutes fire protection. vat Enter postcode for local availability Collection Select collection branch for local availability Showing 17 items of 7 The characteristics of fire-rated plasterboard are: Non-combustible Easy to install Enhanced acoustic performance Minimum fire resistance time of half an hour to up to four hours Low thermal conductivity Enhanced fire emergency protection Using Fireproof Plasterboard Fireproof plasterboards can be used for walls, partitions, and ceilings. Select from a broad range of looks and acoustic options to meet your design and fire reaction requirements. Most Type X drywall has a one-hour fire rating. There are strict Building Regulations in place, designed to prevent the spread of fire and giving occupants time to escape. For this reason, steel beams are covered in either two layers of plasterboard of one single layer or fire-rated plasterboard. Is pink plasterboard fireproof? Suitable for mounting up to 1,000mm (1m) from floor level. From ADB, 2020 amendments, a ceiling in a 2 storey residential class 1. no specific fire resistance or 30 minutes fire resistance, which can normally be achieved with the use of one layer of 12.5mm plasterboard. The double normal plasterboard he refers to is the equivalent to 1 fireline plasterboard I normally put csl wood noggings in steel (which is a skill in itself) leave slightly proud to pop a couple of screws from underneath and on front..when money starts to run dry on this kind of project id advise try and save money on the kitchen appliances and units etc to pay a plasterer to do and finish . I-joists don't perform the same as traditional timber construction in a house fire. Fire protection and Fire Stopping - using non-combustible stone wool, ROCKWOOL products can offer fire protection from 30 up to 120 minutes, in the event of a fire. Underwriters Laboratories Inc. (UL) Classification as to fire resistance (30-minute and 1-hour fire-rated walls), surface-burning characteristics and noncombustibility Comply with ASTM C1396, Standard Specification for Gypsum Board, for 5/8 in. Our adjustable sliding pocket door kits are suitable for doors between 626mm - 1500mm wide and up to 2700mm high. In a BS 476-20 fire test, partitions are generally constructed to no more than 3m in height. Stylish ceilings that don't compromise on safety. Building Regulations Approved Document B and supporting documentation (such as HTM05 and BB100) require these separate 'elements' of the building to provide minimum periods of fire resistance, expressed in minutes (usually 30, 60, 90 or 120). the capco fireguard walling system achieved a 30 minutes fire resistance rating (frr) as a load bearing wall as the load bearing elements (beta studs) reached the critical temperature of 375c at 36 minutes and may therefore be used as a building system in single-storey buildings as a non-load bearing wall the system achieved a 60 minutes frr Fire Resistant Wall Panel Fire resistant plasterboard is only suitable for lightweight fire rated applications. Fire-Resistant Internal Finishes For all structural elements, such as floors, walls and beams, fire resistance of at least 30 minutes is required. 1 In excess of 30 or 60 minutes fire rating. The FRL is the ability of a building element to withstand a fire under test conditions for a certain period of time and consists of the three criteria listed below: structural adequacy integrity The Siniat Fire Board Tapered Edge Plasterboard is manufactured from high-quality gypsum material that ensures the durable life. There is less material to burn once the protective layer of plasterboard has failed, causing a floor to collapse sooner. Pink paper face and grey reverse side paper, suitable for direct decoration. When combined with Gyproc systems, Gyproc FireLine can offer up to 120 minutes resistance. Normally two layers of plasterboard with a skim will give the required fire resistance. M Master of None Joined 31 Oct 2007 Messages 426 Reaction score 21 Location Edinburgh Country 14 Feb 2010 #7 Typically the requirement for ceilings are either 30, 60 or 90 minutes and in each instance the ceiling joist spacing and plasterboard specification will be configured to achieve the required duration of fire resistance. Fire is a very common, unpredictable disaster. Knauf Fireshield Fire Resistant Plasterboard Tapered Edge (various sizes) As low as 14.69 Inc. VAT GYPROC Fireline Plasterboard Tapered Edge Various Sizes Out of stock GYPROC Fireline Plasterboard Tapered Edge 3000 x 1200 x 12.5mm 14.66 Inc. VAT Out of stock Knauf Fireshield Fire Resistant Plasterboard Square Edge (various sizes) Out of stock I-joist and plasterboard combinations have been extensively tested and certified to achieve 30, 60 and 90-minute fire ratings. Using different combinations of board and insulation, various system options are available with fire resistances of 30, 60, 90 or 120 minutes. Is 12.5 mm plasterboard fire rating? Vision panels up to 300 x 200 or 600 x 100mm. Product Overview Fyrchek's glass fibre-reinforced core enables it to maintain structural integrity when subjected to direct flame making it an ideal board for use as part of a fire rated wall or ceiling system. Depending on the size, height, location and type of property, walls and ceilings need to provide 30, 60, 90 or 120 minute fire protection. Key facts Resists fire to allow for safe evacuation A full 30 minutes fire resistance is achieved by constructing non-load bearing partitions with: - Minimum softwood studwork of 75 x 38mm at maximum 600mm centres. 30 minute and 1 hour door leaves are of 'no metal' construction type, allowing for easing hanging and lock preparation. Standard 12.5mm plasterboard and 3mm skim on one side of the stud will give 30 minutes on that side of the partition. Plasterboard cannot be called fire-rated plasterboard per se. You may have to provide an additional skim coat or additional plasterboard to the ceiling. When working with SkyLofts we advise every step of the way with fire regulations and make sure your conversion complies. Well-Known Member Dec 30, 2014 #2 im sure normal boards are 30 mins and fireline are 60 Jurek Private Member Dec 30, 2014 #3 yes, you need two layers scottie5 Private Member Dec 30, 2014 #4 RobJack said: Anybody know how long gypsum 12.5mm pink fire board is rated to in minutes. Specifications The basis of my conclusion is that I used to run a fire testing lab, & have seen 1000+ fire resistance tests. A single sheet of 12.5 mm fermacell gypsum fibre board either side of a metal or timber stud will give a 30 min. 1- 2hr fire tested access panels. Free next day delivery. BENEFITS High-quality lip seal Intumescent seal protecting against gas, smoke and flames in . Building regulation Part B specifies the level of fire protection required within different types of properties. . 1hr Fire Rated Plasterboard Access Panel with Beaded Frame - FlipFix Access Panel . The arrangement should ensure that the public can turn their backs on a fire and leave the building safely, progressing through areas of decreasing fire risk. A wide range of fire rated access panels or fire rated access hatches with a variety of stocked sizes. The 15mm board's superior performance makes it ideal for spaces with greater fire resistance requirements, such as high rise residential buildings. But strictly, this will need a noggin or stud behind every board joint. This is achieved by the addition of glass fibres and other additives in the core when the boards are manufactured. 12.5mm Knauf Fire Panel Tapered Edge Plasterboard 2400mm x 1200mm IN STOCK 14.09 inc VAT Add to Basket 15mm Knauf Fire Panel Tapered Edge Plasterboard 2400mm x 1200mm 17.28 inc VAT Add to Basket 12.5mm Knauf Fire Panel Square Edge Plasterboard 2400mm x 1200mm 14.09 inc VAT Add to Basket Kick panels of stainless steel to selected height. Wrapped in a distinctive pink paper liner, Firestop plasterboard has been specifically formulated for use in fire rated building systems. When a structural fire rating is needed from a suspended ceiling, it is usually either for 30 or 60 minutes - but this rating is less often required. Vermin proof wire mesh 80% free area. Because (assuming standard wallboard) the two layers will have fallen off within 30-40 mins. Is 12.5 mm plasterboard fire rating? The finished ceiling surface can be painted, vinyled or wallpapered. Our fire-rated plasterboard are available in different thicknesses, usually . (c) property doesn't require anything more than 30 minutes fire resistance and this can be achieved with 12.5mm standard plasterboard. MASTERBOARD is off-white in colour and has a smooth finish on one face with a sanded reverse face. 30 minute fire rated sliding pocket door for single FD30 rated fire doors. Thereof, what is the fire rating of plasterboard? Firestop is utilised in Multiframe, Partiwall, IntRwall and other proprietary systems providing lightweight fire and acoustic performance. Floors To obtain the necessary 30-minute fire separation between the ground and 1st floor (including . GLAZED PANEL & FIRE PERFORMANCE: This plasterboard is also an acoustic grade board and can be used in systems where acoustic separation is specified. Loft Conversion Church Crookham. Gyproc FireLine 15mm plasterboard resists fire and stays stable for longer to allow more time for a safe exit. Fire performance from 30-120 minutes. Fire Grilles tested to: BS 476: Part 22 1987. 30 MINUTE FIRE RATED PLASTERBOARD. FIRE RATED SUSPENDED CEILING KIT (30 MINS) - ARMSTRONG TATRA 600 X 600MM SQUARE EDGE. (15.9 mm) and non-Type X gypsum wallboard Adaptability for design - smart fibres in stone wool can adapt to gaps and uneven surfaces, providing total coverage and preventing penetration. For more information, view our resources below. Varying degrees of fire resistance from 30 minutes upwards can be achieved depending on the type of system they are incorporated in and what thickness . Please note this item is made to order, lead times are usually 10-14 days. If you need 30 minutes from the plasterboard alone, you'll need at least . Using different combinations of board and insulation, various system options are available with fire resistances of 30, 60, 90 or 120 minutes. Both of these give fire protection to a steel beam for so many minutes (usually 90!). Depending on the requirements for your application, any thickness may be utilized; however, a 15mm fire-resistant plasterboard will provide better fire protection than a 12.5mm fire-resistant plasterboard. The standard allows for maximum partition heights above 3m to be . If you are considering a loft conversion in Surrey, Hampshire or South West London then please contact SkyLofts on 01252 500 872 or email info@skylofts.co.uk to discuss your loft potential. BS EN 1363-1 better replicates the way a dry lining system is installed on site. Key facts One of the re- quirements is that the fire load is both inside and out- side the duct, and the fire resistance classification is EI 30. 30 minutes only if required, a single layer of 12.5mm plasterboard with taped joints achieves this in most situations, Frutbunn, Sep 13, 2020 #4 Frutbunn Active Member Bob Rathbone said: Complete the joints with Wickes Plasterboard Joint tape and ready mixed Knauf Fill & Finish Light; Acoustic performance from 56-66 Rw dB (airborne insulation), 68-50 Lnw dB (Impact) and up to Class B absorption. Plasterboard cannot be called fire-rated plasterboard per se. 3) Never design an escape route through a kitchen. If you add mineral stone wool insulation in the void you'll get a 1 hour fire rating (and 52dB). Fire reaction is an important consideration for every ceiling system, no matter how simple or complex. Fire proof your home GTEC Fire Board Services inspection and access points are easily included during design or installation. If you can't acheive this, then it will need to be double boarded (or overboarded), in which case you coud use 9mm board. . Using different combinations of board and insulation, various system options are available with fire resistances of 30, 60, 90 or 120 minutes. GypCeiling MF systems give your building the protection of our SpecSure lifetime warranty. Thermoguard Fire Varnish 30 & 60 Minute System 172.80 186.62 Add to cart More info -10% Thermoguard Wallcoat 30 & 60 Minute System for Plasterboard 144.00 155.52 Add to cart More info -10% Thermoguard Fire Varnish Door Upgrade System 291.20 314.50 Add to cart More info -10% Thermoguard Timbercoat 30 Minute System 152.00 164.16 Add to cart Fire ratings up to 2 hours Applications: Fire-rated industrial external boundary walls in portal framed buildings Suitable for new construction or fire upgrade of existing external wall Fire-rated plasterboard linings can be fixed directly to girts of maximum 2.0BMT and 1200mm spacings The measurement of the product is 2400 x 1200mm (L x W) with 12.5mm thickness. Load bearing internal walls will normally require either 30 or 60 minutes fire resistance, depending on the size and purpose group of the building and/or the fire resistance performance of the elements they . The Metal Furring System (MF Ceiling) is a suspended metal frame which allows for the direct fix of plasterboard sheets to create a smooth and seamless finish. Gyproc 12.5mm WallBoard fixed either side of minimum 63mm x 38mm timber studs at 600mm centres creates a 30 minute fire rated partition to BS476: Part 22. The board's excellent fire resistance rating makes it ideal for lining walls and ceilings in commercial spaces like offices and shopping centres, as well as in low rise housing and new build garages. Under 5 minute fitting thanks to the unique FlipFix device. Please double check your requirements before ordering this product, this item cannot be returned to us. Just flip and fix, its that simple. This is usually achieved by using fire-rated plasterboard and plaster finishes at least 12.5mm thick, or two layers of standard plasterboard at least 9.5mm thick and a plaster set finish. As it is not fireproof, merely fire-resistant, pink plasterboard should not be relied on solely to prevent the spread of fire, but merely to . FAQ. Gyproc 12.5mm WallBoard fixed either side of minimum 63mm x 38mm timber studs at 600mm centres creates a 30 minute fire rated partition to BS476: Part 22. All joints taped and filled or skimmed. The minutes show the length of time fire plasterboard can withstand fire without breaking down. Escape through a kitchen could lead to a second seat of fire if, for example, a pan of oil were knocked over in the panic to escape. Each kit allows you to . As an added benefit, Type X drywall absorbs sound slightly better and is slightly stronger than conventional 3/8-inch or 1/2-inch drywall. It is formulated without inorganic fibres and does not contain formaldehyde. Gyproc 12.5mm WallBoard fixed either side of minimum 63mm x 38mm timber studs at 600mm centres creates a 30 minute fire rated partition to BS476: Part 22.